Related CLI commands
Entity
event
event
event
event
event
event
event
event
Local Logging parameters
A secondary log file can be created on a USB flash drive and events will be appended to this log
file. This facility is useful if an extended logging period is required where, the normal eventlog.txt
file would overwrite early events before the operator has had a chance to view them. The
secondary log file can be limited in size or allowed to fill the USB flash drive. Once the log file is
full, earlier events will be pruned from the end of the file to allow new events to be added.
To configure the local logging parameters, set the following values in the web interface:
Local Drive to log to
This parameter determines the drive letter where the USB flash drive is located. This is
designated "u" for a USB drive.
Log filename
This specifies the name of the file for the secondary event log.
Log size
Digi TransPort User Guide
Instance
Parameter
n
sms_to
n
sms_trig
n
sms_to2
n
sms_trig2
n
sms_to3
n
sms_trig3
n
sms_temp
n
sms_max
Values
A valid mobile number
such as 447871445677
0 – 9
A valid mobile number
such as 447871445677
0 – 9
A valid mobile number
such as 447871445677
0 – 9
event.sms (template file
stored in the compressed
.web file)
0 – 255
Event Settings parameters
Equivalent Web Parameter
Send SMS messages to
If the event priority is at
least
n
Send SMS messages to
If the event priority is at
least
n
Send SMS messages to
If the event priority is at
least
n
Use SMS template
Send a maximum of
n
messages per day
SMS
384