4.23

Copying the Show Data between 2 Scan Operator FX II

It is possible to transfer all memory contents of one Scan Operator FX II to another one.
Use the following steps to transfer the memory:
1. Both controllers are switched Off
2. Connect both devices with a DMX Cable (XLR 3-Pin Male-Male)
3. Make sure that all Midi cables are unplugged
4. On the receiving controller hold down the buttons „Fixture 7" and „Fixture 12"
simultaneously while switching it On.
5. The display now shows "Serial/Rec. 000% ". The desk is ready to receive data.
6. On the sending controller hold down the buttons "Fixture 1" and "Fixture 6"
simultaneously while switching it On.
7. The Display of the sending controller is showing "Serial/send xxx%" and the
percentage value will count up slowly. The value shown in the controller that is
receiving the date should increase as well. The transmission procedure lasts
approximately 90 seconds.
8. The transmission has finished successfully, when both units have reached 100%.
In the case of errors:
It might happen that the receiving unit stops with the progress below 100% - If that
happens, try to restart the data transmission.
If the waiting controller shows no reaction, although the other unit is sending data, then
the error probably comes from a faulty DMX connection!
54/57