Note
See "Light and Appliance
Controls" to program a Key-
chain Touchpad to activate a
Universal Module controlled
device.

Programming

Note
Do not remove panel power
while in program mode. Pro-
gramming changes are
saved only when exiting pro-
gram mode (closing the
panel cover).
Note
If Option 8: Phone Lock is
on, options 04, 05, 06, 08,
09, 12, 13, 54 and Dealer
Code will not reset to their
defaults.
13
4. Connect the module terminals to the desired device terminals.
5. Plug the universal module into a wall outlet.

Sensor Installation

Program sensors and devices before you install them. Use the following section to program the
panel and add the sensors to panel memory.

Entering Program Mode

There are 2 codes you can use to enter program mode.
Utility Access Code 1 (Dealer Code)
Depending upon how Option 54 is set, the default utility access code is 654321, 54321, 4321
(factory default), or 321. This code can be used for all programming.
Utility Access Code 2 (Installer Code)
Depending upon how Option 54 is set, the default access code is 654321, 54321, 4321 (factory
default), or 321. This code is limited to changing all but the following: Utility Access Code 1,
Options 4, 5, 6, 8, 9, 12, 13, 54, and 69.
1. Open the panel cover.
2. Enter Utility Access Code 1 or 2 using the numbered keys.
The panel is now in program mode. Follow the programming arrows on the panel label. The
system prompts you through programming steps with beeps and voice messages.
¾
Program the panel in this order:
1. Set the panel clock.
2. Add (learn) sensors.
3. Set House Code and Light & Appliance Controls (Entry/Exit activated lights, Sensor acti-
vated lights, Time activated lights).
4. Change numbered Options as needed.

Exiting Program Mode

Close the cover to exit program mode when you are finished programming.
!
Do not power down the panel while in program mode or all programming will be lost.
The panel stores programmed information only when you exit program mode (close
the cover and leave closed for at least 5 seconds.
Caution

Reset Memory to the Factory Defaults

1. Open the panel cover and enter Utility Access code 1.
2. Unplug the transformer and disconnect the battery.
3. Simultaneously press and hold Cancel, Clock Set, and
Minutes +.
4. Restore power to the panel with either the battery or the transformer while pressing these
three buttons. The panel announces "Hello. System XX OK." Release the buttons.
5. Connect the remaining power source to the panel.

Set the Clock

1. Press Clock Set from the Start Menu.
2. Press the Hours + and
announces the correct hour.
3. Press the Minutes + and
announces the correct minutes.
4. Press Done. The panel announces the set time.