Button Modules - Avaya IP Office 8.1 Product Description

Table of Contents

Advertisement

Button Modules

IP Office supports a number of different button modules to provide telephones with additional programmable
buttons. The limits stated below are those applicable for the IP Office 4.2 2Q 2009 maintenance release and
higher.
BM32: (1616)
·
Up to 32 BM32s supported (32 buttons each, up to 1024 buttons).
DSS4450: (4412D+, 4424D+)
·
Up to 8 DSS4450 modules per system (maximum of 2 per DS expansion module, including the
IP406v2) (50 buttons each, max 400 buttons).
DBM32: (1416)
·
Up to 32 DBM32s supported (32 buttons each, up to 1024 buttons).
EU24/EU24BL: (4620, 4621, 5420, 5620, 5621, 4620, 4621, 5620, 5621)
·
Up to 8 EU24s per system (24 buttons each, max 196 buttons).
SBM24: (9630G, 9640, 9640G, 9650, 9650C)
·
Up to 42 SBM24s per system (24 buttons each, up to 1008 buttons).
BM12: (9508. 9608, 9611 9641)
·
Up to 42 SBM24s per system (24 buttons each, up to 1008 buttons).
BM12: (9608, 9611, 9641)
·
Up to 42 SBM24s per system (24 buttons each, up to 1008 buttons).
LCD IP key Expansion module for 1200 telephones (1220, 1230)
·
Up to 82 LCD-IP KEMs per system (12 buttons each, up to 1008 buttons).
LED IP key Expansion module for 1200 telephones (1220, 1230)
·
Up to 56 LED-IP KEMs per system (18 buttons each, up to 1008 buttons).
LCD IP key Expansion module for 1100 telephones (1120, 1140)
·
Up to 56 LCD-IP KEMs 24s per system (18 buttons each, up to 1008 buttons).
T3 Series: (All T3 telephones)
·
Up to 30 T3 DSS modules supported. (36 buttons each, up to 1080 buttons). T3 DSS buttons are not
included in the overall system limit for additional button module buttons.
XM24: (6416+, 6424+)
·
Up to 10 XM24 units per system (maximum of 2 per DS expansion module, including the IP406v2)
with a maximum of 1 per 6416+/6424+ phone (24 buttons each giving a maximum of 240 XM24
buttons).
T24 KIM (Key Indicator Module) (T7316)
·
Up to 42 T24 KIMs per system (24 buttons each, up to 1008 buttons).
The maximum number of additional button module buttons per system is 1024 (regardless of if the buttons are
configured for use or not). Only exception is use of T3 DSS only where, if no other button modules are used, a
total of 1080 buttons is supported:
12 x BM32 + 5 x EU24 + 20 x SBM24 is allowed (984 buttons in total).
·
15 x T3DSS + 15 x BM32 is allowed (1020 buttons in total).
·
but NOT 8 x BM32 + 10 x EU24 (because it exceeds the maximum number of 8 EU24s, even though
·
total buttons < 1024).
and NOT 14 x BM32 + 5 x EU24 + 20 x SBM24 (total 1048 buttons, this exceeds the maximum 1024
·
buttons per system).