Report Individual Bad Jets - Oce CS7075 User Manual

Table of Contents

Advertisement

4-20
3. When the calibration pattern has printed, the control panel
displays a menu with the following options:
◆ Report individual soft bad jets — enables you to report
a "soft" bad jet, which can be automatically reenabled if
AutoJet finds it working.
◆ Report individual hard bad jets — enables you to report
a "hard" bad jet, which will not be checked or reen-
abled by AutoJet.
◆ Clear individual bad jets — enables you to clear (mark
as good) a jet.
◆ View current bad jets — lists the bad jets on a given
printhead.
◆ Clear all bad jets — clears (marks as good) all jets cur-
rently marked as unusable.
A "soft" bad jet is a jet that you believe is temporarily out,
based on past performance. A "hard" bad jet is a jet that you
believe is permanently out.
Select an option and follow the corresponding procedure
below.

Report Individual Bad Jets

When you select Report Individual Bad Jets, the control
panel displays the following prompt:
Press Proceed to report a bad jet.
4. Press  and  to select a head number, then press 
(Proceed).
Head 1:
Manual Calibrations

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs7100

Table of Contents