Description
A-MS-6 Thickness Sensor Discon-
nected
W-MS-1 Media Low
W-MS-4 Media Advance Switch
Detected
W-MS-6 Media Too Wide
(PR) Pinch Rollers
A-PR-1 Pinch Rollers Up
(PC) Printer Calibration
W-PC-2 Media Replaced - Recali-
brate
W-PC-3 Head Height Changed -
Recalibrate
W-PC-4 Jets Not Replaced
W-PC-6 Uncalibrated Pass Mode
W-PC-7 Platen Width Not Known
W-PC-8 Thickness Sensor Uncali-
brated
B-12
Table B-1. Action and Warning Messages
Cause
The media thickness sensor is dis-
connected or reading an invalid
value.
Between 10 feet (3 meters) and 1
foot (30 cm) or less of media
remains.
Media Advance Switch on back of
printer was depressed.
Media is too wide for printing.
The pinch rollers are up, in the
media release position.
Media advance accuracy may need
to be recalibrated.
Change in head height has invali-
dated calibration.
Not all missing jets could replaced.
Print mode selected has media
advance rate different from the cal-
ibrated advance rate, which may
cause banding.
Measurement was reset or not per-
formed.
The media thickness sensor has not
been calibrated.
What to do
Ensure that the media thickness
sensor is connected and calibrated.
If the problem persists, contact
your Océ Authorized Service Pro-
vider or Océ Technical Support.
Load media.
Use the Load or Unload button to
finish operation.
Use narrower media. See manual
for specifications.
Lower the pinch rollers and lock
them into the appropriate slot.
Refer to the current media settings
for determining the correct slot. If
media is out, run the media load
procedure.
Calibrate media feed if media type
was changed.
Run Autoset.
Prime/clean cartriges, or increase
the print mode quality.
Calibrate media feed.
Restart printer to measure platen
width.
Calibrate the sensor using the
menu item in the service menu.