Electrical Power
Power used: 200-240VAC, 50/60 Hz, 16 Amps maximum
Required electrical circuit:
220 VAC, 20 Amps, with NEMA L6-20R locking wall receptacle (North America and Japan),
OR
220 VAC, 16 Amps, single phase, with IEC 60309 wall receptacle (Europe)
NEMA L6-20R
IEC 60309
locking wall receptacle
wall receptacle
(North America/Japan)
(Europe)
North America: If your building receives power from a standard three-phase supply, note
that the printer will use only two of the three phases. This means that your building's three-
phase power transformer may have an unbalanced load. Check with your electrician to ver-
ify that your building has sufficient capacity for this unbalanced load.
Optional auxiliary power for vacuum system:
Supplied 24 volt DC power supply with universal adapters, connected from the 24 VDC jack
on the vacuum/pressure assembly to either of two options:
1. UPS — customer-supplied uninterruptible power supply, output 100-240 VAC, 50/60 Hz,
minimum of 15 watts of power, provides battery backup to the vacuum system in the event
of a power failure.
2. Wall outlet — 100-240 VAC, 50/60 Hz, provides temporary power to the vacuum system
when it is necessary to power down the printer for service.
Required power cord (supplied with printer):
North American (UL/CSA approved), length 8.2 feet (2.5 m), OR
European (Harmonized), length 8.2 feet (2.5 m)