KEP MMI-1500 Installation & Operation Manual page 38

Mmi-touchscreen series
Table of Contents

Advertisement

MMI model: Select the unit by model number from the dropdown.
KEP Part#
MMI1500T (640 x 480)
MMI1500S (640 x 480)
MMI1500M (640 x 480)
MMI1050 (640 x 480)
MMI850T (640 x 480)
MMI850 (640 x 480)
MMI750T (320 x 240)
MMI750 (320 x 240)
MMI730T (320 x 234)
MMI720 (320 x 240)
Notes:
Changing model type effects how windows are displayed.
EasyBuilder does not scale windows when display size is changed.
Example: Changing from a 640x480 to a 320x240 display clips the windows so that only the upper left corner is
shown. Changing from a 320x240 to a 640x480 display shows the window's objects in the upper left corner.
EasyBuilder does not compensate colors so that the display is readable when changing from Color Models to Grayscale
Models.
Use the MMI850 selection to program the discontinued MMI1500S.
Use the MMI1500M selection to program the discontinued MMI1050.
Use the MMI750T selection to program the MMI750T and MMI750T-HB.
KEP recommends that you develop a project for its target hardware platform.
(There is no utility to automatically resize a project for a larger or smaller screen.)
Serial Port I/F: Select the PLC port's type of hardware communications. The HMI activates the
corresponding port and configuration on the back of the unit.
Serial Port I/F
Description
RS-232
Communications to the controller are through the PLC[RS-232] port. (Pins
2,3 & 5)
RS-485 default
Communications to the controller are through the PLC[RS-485] PC[RS-232]
port. This can be 2 wire or 4 wire depending on the PLC type. When unsure
select RS-485 4W or RS-485 2W.
RS-485 4W
Communications to the controller are through the PLC[RS-485] PC[RS-232]
port. (Pins 1~5)
RS-485 2W
Communications to the controller are through the PLC[RS-485] PC[RS-232]
port. (Pins 1,2 & 5)
Ethernet (Option)
Communications to the controller are through the optional Ethernet port.
Note: RS-485 communications can be forced to 4 wire or 2 wire types. This is practical when communications adapters are
used to connect several devices to one PLC. If left at the default, it uses the PLCs default configuration.
Note: For additional information about communication configurations for a selected PLC, see the Controller Reference
Guide section that refers to that PLC.
Note: The PLC[RS-485] PC[RS-232] port is a dual port and serves as the programming port for the MMI. This port is also
used for Master/Slave communications (see below).
Display Type
10.4" TFT 256 Color
10.4" STN 256 Color
10.4" STN 4 Shade Grayscale
9.4" STN 4 Shade Grayscale
7.7" TFT 256 Color
7.7" STN 256 Color
5.7" TFT 256 Color
5.7" STN 256 Color
5.7" TFT 256 Color
5.7" STN 4 Shade Grayscale
OEM Part#
MT510T...
MT510S...
MT510L...
MT509L...
MT508T...
MT508S...
MT506T...
MT506S...
MT506T46
MT506L...
30

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mmi-750Mmi-730Mmi-850

Table of Contents