KEP MMI-1500 Installation & Operation Manual page 108

Mmi-touchscreen series
Table of Contents

Advertisement

LB Address
Description
9050
Toshiba T/C write enable bit. The user:
Sets ON to enable writing to T/C bits ON & OFF.
Sets OFF to disable T/C writing.
T1/T1S user's manual NOTE:
When writing to Timer/Counter registers, the
Timer/Counter's device data should be added to the
written data. (2 bytes each, corresponding to the
Timer/Counter's register)
9051
Enable or Disable the touchscreen when the
Backlight is turned OFF. The user:
Sets ON to disable touchscreen when Backlight
is turned OFF.
Sets OFF to keep touchscreen enabled when
Backlight is turned OFF.
9052
Write back enable PLC Control, Change window.
The user:
Sets ON to disable write back to PLC.
Sets OFF to enable write back to PLC.
9055
Disconnect action – PLC communications. The user:
Sets ON to continuously retry any write to PLC
command.
Sets OFF to stop any write to PLC commands.
9056
Disconnect action –Touchscreen The user:
Sets ON to enable touchscreen.
Sets OFF to disable touchscreen.
Bits LB9060 ~ 9069, 6080 and 6081 are used for detecting Numeric Input Extend and ASCII Input Extend presses. See the
following page for Touchscreen map.
9070
MITSUBISHI J2-S10 driver control
Effects local data being added to 'R' or subtracted
from 'R'.
Set bit ON to disable add/subtract operations
Set bit OFF to enable add/subtract operations
Valid range: 0x00800000 to 0x7FFFFFFF (8388608
to 2147483647 decimal)
Invalid range: 0xFF799999 to 0x80000000
(-8388608 to –2147483648 decimal).
9071
MITSUBISHI J2-S10 driver control
Write options for 'R'. The user:
Sets bit ON to write to EPROM.
Sets bit OFF to write to RAM.(default)
9090
Event Log Clear The user:
Sets bit ON to write to clear entries from the
Event Log. This includes entries stored in RW
memory, if enabled.
9091
Adjusts contrast lighter one shade. The user:
Sets bit ON to activate.
9092
Adjusts contrast darker one shade. The user:
Sets bit ON to activate.
NOTE
When setting the Timer/Counter's
device to ON, use '01'; for OFF use
'00'. (read/write)
OFF is the default mode.
(read/write)
This applies to Change Window
control only.
(read/write)
When HMI is disconnected from the
PLC, it acts according to the state of
this local bit 9055.
(read/write)
When HMI is disconnected from the
PLC, it acts according to the content of
this local bit 9056. (read/write)
Due to the protocol limitation of J2-
S100 for 'R' registers. A value
between 0x00800000 and
0xFFFFFFFF(inclusive) cannot be
written to R because it creates an
error.
(read/write)
(read/write)
After the Event log is cleared, this bit
auto resets to OFF.
(read/write)
After the contrast is made lighter, this
bit auto resets to OFF. Hardware
Version 4.5 only.(read/write)
After the contrast is made darker, this
bit auto resets to OFF. Hardware
Version 4.5 only.(read/write)
100
Version
Ver 1.5
Ver 1.6
Ver 1.6
Ver 1.6
Ver 1.6
Ver 1.6
Ver 1.6
Ver 2.5.2
Ver 2.6.0
Ver 2.6.0