Wiring for cable connections using Matsushita FP1, FP2, FP2SH, FPM CPU's with RS232 D-Sub 9
16.24.3.3
Female Plug ports.
KEP Part#: (Not Available) (D-Sub 9 Male Socket to D-Sub 9 Male Socket Cable)
HMI PLC[RS-232]
2 TXD
3 RXD
5 GND
16.24.3.4
Wiring for cable connections using MATSUSHITA FP0 CPU's with RS232 Screw Terminal ports.
KEP Part#: (Not Available) (D-Sub 9 Male Socket to Flying leads Cable)
HMI PLC[RS-232]
2 TXD
3 RXD
5 GND
16.24.3.1
Wiring for cable connections using Matsushita FP3 CPU's with RS422 D-Sub 15 Male Socket ports.
KEP Part#: (Not Available) (D-Sub 9 Female Plug to D-Sub 15 Female Plug Cable)
HMI PLC[RS-485]
1 RXD-
2 RXD+
3 TXD-
4 TXD+
5 GND
Note: Graphic representation may not reflect the actual appearance of the finished cable.
Connect to Matsushita FP1, FP2, FP2SH or FPM CPU Port
3 RXD
2 TXD
7 GND
4 RTS
5 CTS
8 CD
9 ER
Shield
Earth Ground
Connect to Matsushita FP0 Screw Terminal Port
1 R
2 S
3 G
Shield
Earth Ground
Connect to Matsushita FP3 CPU Port
9 TXA-
2 TXB+
10 RXA-
3 RXB+
7 GND
4 RTS+
5 CTS+
11 RTS-
12 CTS-
Shield
Earth Ground