KEP MMI-1500 Installation & Operation Manual page 244

Mmi-touchscreen series
Table of Contents

Advertisement

16.16.4 Device address
Bit/Word
Type
B
End_Command
B
Relay(bit)
W
DM
W
TM
W
Relay
W
Timer_Contact
W
Timer_Current
W
Timer_Preset
W
Counter_Contact
W
Counter_Current
W
Counter_Preset
The PLC's memory range may vary within the range supported by the driver. Use appropriate addresses.
Address Format
Range
d
d: 0
dddbb0
dddbb:0~19999
bb: 00~15
dddd
dddd: 0~1999
dd
dd: 0~99
ddddd
ddd: 0~19999
ddd
ddd: 0~999
ddd
ddd: 0~999
ddd
ddd: 0~999
ddd
ddd: 0~999
ddd
ddd: 0~999
ddd
ddd: 0~999
The End_Command is used to suspend or enable
communications to the PLC. Communications are
automatically started when the HMI is powered up.
Must add "0" after the address
Data Memory
Temporary Memory
Relays
Timer Bits
Timer Accumulator
Timer Preset
Counter Bits
Counter Accumulator
Counter Preset