D7212GV3 | Operation and Installation Guide | 4.0
Releasing the reset pin from the closed position
resets the control panel. The control panel resets all
its timers, counters, indexes, and buffers. Any points
that restore after a reset do not generate Restoral
Reports.
If the reset pin is placed in the disable position when
all areas are armed, there must be an entry in the
Answer Armed program item. Refer to RPS
Parameters in the D7212GV3 Program Entry Guide
(P/N: F01U170808).
Locking the pin in the disable position applies power
to the control panel and charges the battery while the
detection devices and keypads are installed.
Figure 4:
Reset Pin
1 - Reset pin locked (closed.
2 - Reset pin normal (open)
4.6

Completing the Installation

If not already complete, make the earth ground
connection to Terminal 10 and lock the reset pin in
the closed position.
4.6.1

Charging the Battery

Connect the battery, then the transformer to allow the
control panel to charge the battery while you complete
the installation. Refer to Section 5.0 Power Supply on
page 20 for instructions.
On-board Buzzer Sounds at Power Up and Reset:
The system performs a series of self-diagnostic tests
of hardware, software, and programming at power up
and at reset. The buzzer on the control panel sounds
during the tests. The self-diagnostics tests complete
in approximately 1 to 3 sec.
If the control panel fails any test, the buzzer continues
sounding and a System Trouble message appears at
the keypads.
16
Installation
Touch Terminal 10 First: If the on-board buzzer
sounds briefly when the control panel is touched, any
static charge you carry discharges to the control
panel.
Avoid electrostatic discharge. Always touch
Terminal 10, the earth ground connection,
before beginning work on the control panel.
If the control panel receives an electrostatic
discharge, it might generate Watchdog Reset and
Param Fail events.
4.6.2

Installing and Wiring Detection Devices

Install and wire detection devices and keypads at their
locations throughout the premises. Do not connect
the control panel yet.
Section 8.0 On-Board Points on page 28 contains
instructions for wiring the on-board points to detection
devices. Section 11.0 Arming Devices on page 44
contains instructions for wiring the keypads.
Instructions for wiring the off-board point POPIT
sensor loops are found in the instructions packaged
with the POPIT modules.
4.6.3

Installing Modules and Relays

1.
Power down the unit by unplugging the
transformer and disconnecting the battery.
Always power down the unit when installing
modules or relays, or when making wiring
connections to the control panel.
2.
Install and wire any modules required for the
installation as described in the module's
installation instructions.
Instructions for the D8125 POPEX Module,
D8128D OctoPOPIT Module, D8129 OctoRelay
Module, and D811 Arm Status Relay Module
appear in this guide.
Refer to Section 9.0 Off-Board Points on page
for D8125 and D8128D instructions. Refer to
Section 10.0 Off-Board Relays on page 43 for
D8129 and D811 instructions.
3.
If using the power outputs at Terminals 7 or 8,
refer to Section 6.4 Programmable Power Output
Terminals 6, 7, and 8 on page 24 for
instructions.
4.6.4
Connecting the On-board Points and
Keypads
Connect the on-board points and keypad wiring to the
system. Refer to Section 8.0 On-Board Points on
page 28 and Section 11.0 Arming Devices on page
44 for instructions.