OfficeServ 7400
TECHNICAL MANUAL
• RRQ FAIL TIME: Programs the time frame to re-send Registration Request RAS
(RRQ) messages to a gatekeeper. Default is 30 seconds. The range is 1~99.
• GRQ SEND: Select ON or OFF for usage of Gatekeeper RAS Request (GRQ)
messages.
• USE MULTI E.164: When set to "Enable" the E.164 identifier can be assigned to
multiple lists (32 max).
• E.164 LISTS (1): This is the E.164 identifier used by the H.323 trunk when
registering with the gatekeeper (max 32 lists with 16 digit string length).
• GK REGISTERED: Displays GK registration status.
PROGRAM KEYS
UP & DOWN
KEYPAD
SOFT KEYS
SPEAKER
ACTION
1. Press TRANSFER 836.
Display shows the first available option.
Press UP or DOWN key to select an option
OR press the RIGHT soft key to move cursor
2. Press UP or DOWN key to select an option
OR press RIGHT soft key to move cursor.
3. Press UP or DOWN key to select an option
and press RIGHT soft key to enter data and
move cursor to the Step 1 position.
4. Press UP or DOWN key to select an option
and press RIGHT soft key to store entry and
move cursor
OR
5. Press TRANSFER to store and exit
OR
Press SPEAKER to store and advance to next
MMC.
MMC: 836
Used to scroll through options
Used to enter selections
Move cursor left and right
Used to store data and advance to next MMC