Field Service Ver. 1.0 Mar. 2005
18.3.24
Printer Monocolor: 0.5-mm-pitch uneven image
A. Typical Faulty Images
B. Troubleshooting Procedure
Step
Section
LPH Assy
1
4036fs4053c0
Check Item
LED retracting lever is locked in
position.
18. Image quality problem
0.5mm
Result
NO
Slide out the IU and reinstall.
YES Change Imaging Unit.
Action
405