16. Malfunction code
Code
C6102 Scanner Home Sensor
malfunction
C6103 Scanner overrun failure
C6301 Scanner Cooling Fan Motor's
failure to turn
C6704 Scanner Time Out
C6751 CCD clamp/gain adjustment
failure
C9401 Exposure Lamp's failure to turn
ON
C9402 Exposure Lamp turning ON at
abnormal timing
CA051 Standard controller configuration
failure
CA052 Controller hardware error
CA053 Controller start failure
CB001 FAX Board Error 1
CB002 FAX Board Error 2
CB003 FAX Board Error 3
CB051 FAX Board mount failure 1
CB052 FAX Board mount failure 2
CB110 FAX Driver Error: Instance Gen-
eration Error or Observer Regis-
tration Error
CB111 FAX Driver Error: Configuration
Space Initialization NG
CB112 FAX Driver Error: Semaphore
Acquisition, Release Error
330
Item
• The Scanner Home Sensor is unable to detect the
Scanner located at its home position.
• The Scanner Home Sensor is unable to detect a
Scanner even when the Scanner Motor has been
driven to move the Scanner over the maximum
traveling distance.
• The Scanner Home Sensor detects the Scanner
when the Scanner has moved 5 mm from the
position, at which it blocks the Scanner Home
Sensor.
• The Scanner Home Sensor detects the Scanner
at its home position during a period of time that
begins with the time when a prescan command
and a scan preparation command are executed
and ends when a home return command is exe-
cuted.
• The Fan Lock signal remains HIGH for a predeter-
mined continuous period of time while the Motor
remains stationary.
• Image data is not input from the Image Process-
ing Board (PWB-C) to the MFP Control Board
(PWB-MFPC).
• The adjustment value is 0 or 255 during a CCD
clamp adjustment.
• The peak value of the output data is 64 or less
during a CCD gain adjustment.
• The output from the CCD Sensor is a predeter-
mined value or less during CCD Sensor gain
adjustment.
• The average output value of the CCD Sensor with
the Scanner at its standby position is a predeter-
mined value or more at the end of a scan job.
• The controller of the MFP Control Board (PWB-
MFPC) is faulty.
• A controller hardware error is detected in the net-
work I/F.
• A controller start failure is detected in the control-
ler interface.
See FK-502 Service Manual.
Field Service Ver. 1.0 Mar. 2005
Description
Rank
B
B
B
C
B
A
A
C
C
C
C
C
C
C
C
C
C
C

Hide quick links: