10. Service Mode
10.12.8

Memory/HDD State

Functions
• To display the condition and amount of the memory and Hard disk.
Use
• Use to check the condition and amount of the memory and Hard disk.
Setting/
• When an add-on memory is mounted, the machine automatically recognizes it
Procedure
and displays its capacity.
10.12.9

Color Regist

Functions
• To check each of C, M, Y, and K for color shift amount.
• The data is updated after a color shift correction has been made or color shift adjust-
ment has been completed.
Use
• Use for check when color shift is evident.
Setting/
• For each of C, M, Y, and K, the color shift amount (in X and Y directions) at two loca-
Procedure
tions (one at the front and the other in the rear) and the difference in color shift
amount between the front and rear (X and Y directions) are displayed.
• Display unit: dots
• The shift amount is displayed with reference to K for C, M, and Y, and that for K is dis-
played with reference to an ideal position.

10.12.10 IU Lot No.

Functions
• To display the 10-digit lot number for each of C, M, Y, and K IUs.
• The lot number data is stored in EEPROM of each IU.
Use
• Use for checking the IU Lot No.
Setting/
• The IU lot number is displayed even with the Front Door opened; however, the display
Procedure
is blank, since the machine is unable to read the lot number when the Main Power
Switch is turned ON with the Front Door open. Nonetheless, the lot number will be
displayed when the Front Door is closed.
(The engine obtains the IU lot number information when the Front Door is closed.)

10.12.11 LPH Status

Functions
• To check various information on each of the C, M, Y, and K LPHs
Use
• Use for checking the LPH Status.
Setting/
• LPH Lot No.: LPH lot number (8 digits)
Procedure
• Average Exposure: Average light intensity
• X: Print width accuracy
• Y: Linearity accuracy
• Z: Focus accuracy
• FFT Rank: Print width rank
• LPH Rank: 0 to 5
• If any one change is made from the default value as a result of LPH chip-to-chip cor-
rections, an asterisk "✻" is displayed beside the color identification (C, M, Y, and K)
on the screen.

10.12.12 Adjustment Data List

Functions
• To display the adjustment and setting value set in the main unit.
Use
• Use to check the adjustment and setting value set in the main unit.
286