16. Malfunction code
16.6.113 CEEE1: MSC undefined malfunction occurring
MFP Control Board (PWB-MFPC)
Step
Check the connectors on PWB-MFPC for proper
1
connection and correct as necessary.
2
Change PWB-MFPC.
16.6.114 CEEE2: Scanner Section undefined malfunction
Scanner Assy
Step
Correct the connector connection between PWB-
1
A and PWB-C if faulty.
2
Change PWB-C.
3
Change PWB-A.
16.6.115 CEEE3: Engine Section undefined malfunction
Control Board (PWB-MC)
Step
Check the PWB-MC connector for proper con-
1
nection and correct as necessary.
2
Change PWB-MC