Field Service Ver. 1.0 Mar. 2005
7.

Test mode

7.1

Test mode setting procedure

<Setting Procedure>
1. Turn OFF the Main Power Switch of the main unit.
2. Flip keys of the DIP switch into the ON or OFF position as necessary. (See Table
below.)
3. Turn ON the Main Power Switch of the main unit.
4. This sets the Finisher into the corresponding Test Mode operation.
<Resetting Procedure>
• Flip all keys of the DIP switch to their respective initial positions and turn OFF, then ON,
the Main Power Switch of the main unit.
7.2

Test mode operations

Test mode operation
Primary paper output tray exit
Secondary paper output tray exit
Third tray exit
Finisher Tray exit
Shifting operation
Aligning Plate operation
Stapling Unit CD movement
Exit Roller/Rolls spacing
Storage Roller/Rolls spacing
Elevator Tray operation
Punch Operation
Punch Hole 2/3 Switching
Sensor test
NOTE
• Whenever the Control Board (PWB-A FN) is to be replaced, take note of the initial
positions of all keys of the DIP switch. After the replacement procedure has been
completed, be sure to flip all keys of the DIP switch on the new Control Board
(PWB-A FN) to their respective initial positions.
DIP Switch (S3)
1
2
3
4
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
7. Test mode
LED
1
2
3
4
Indicates sensor state
●:Blinking ❍:OFF