Cleaning Brush Motor (M22) - Konica Minolta bizhub C450 Service Manual

Hide thumbs Also See for bizhub C450:
Table of Contents

Advertisement

6. Other
[22]
[25]
[27]
[26]
6.3.52

Cleaning Brush Motor (M22)

[1]
[2]
[1]
112
[23]
4036fs2131c1
[24]
4036fs2132c1
4036fs2133c1
[1]
4037F2C103DA
Field Service Ver. 1.0 Mar. 2005
19. Remove two E-rings [22], and
remove the Cover [23].
20. Remove the E-ring [24], and remove
the Gear [25].
21. Remove the two Screws [26], and
remove the Fusing Pressure Roller
Pressure/Retraction Motor [27].
1. Remove the High Voltage Unit/1
mounting plate.
☞ See the procedures 1 to 4 of page
105 "1st Image Transfer Pressure/
Retraction Motor".
2. Remove ten screws [1], and remove
the IR Left Frame [2].