Field Service Ver. 1.0 Mar. 2005
[12]
[11]
[11]
11. Remove the Connector [9].
[9]
4037F2C072DA
12. Turning the IU (C, M, Y, K) drive hub
[10], push it into the locked position
(at four places).
NOTE
[10]
• During the locking procedure, use
care not to touch the LED surface.
• Should the LED surface be
touched, clean it with the LED
Cleaning Jig.
4037F2C073DA
13. Remove four screws [11] and slide
out the LPH Unit [12].
NOTE
• When the LPH Unit is to be
replaced, remove the TCR Sensor
from the old LPH Unit and remount
it on the new one. This step is not,
however, necessary if the IU is
replaced at the same time.
☞ For replacement of TCR Sensor, see
page 119.