6.3.36

PWB Unit

[2]
[3]
92
1. Remove the Right Rear Cover.
☞ 52
2. Disconnect the connector [1].
[1]
4037F2C040DA
3. Remove eight screws [2].
[2]
4037F2C079DB
4. Remove the PWB Unit [3].
4037F2C080DA