5. Mechanical adjustment
5.5

Stapler Phase Adjustment

5.5.1

Adjustment procedure

[1]
[4]
[8]
[10]
[7]
[12]
[11]
[16]
36
4583fs2504c0
[3]
[4]
[2]
[4]
[5]
4583fs2543c0
[9]
[6]
4583fs2505c0
[13]
[14]
[15]
[17]
4583fs2506c0
Field Service Ver. 1.0 Mar. 2005
• Make phase adjustment of the Stapler
following the procedures given below
whenever the Gear or Timing Belt in
front of the Stapler has been replaced
or removed for some reason, since
such replacement or removal will
cause mistiming between the staple
driving by the Staple Driver (the lower
unit of the Stapler) and the staple
clinching by the Staple Clincher (the
upper unit of the Stapler).
1. Remove the Stapler.
☞ 10
2. Remove the E-Ring [1], and remove
the Jam Release Dial 1[2].
3. Remove the Jam Release Dial 2 [3].
4. Remove the three screws [4], and
remove the Stapler Front Cover [5].
5. Remove the Gear Cover [7] from the
Staple Driver [6].
6. Remove the E-Ring [8], and remove
the Side Cover [10] from the Staple
Clincher [9].
7. Remove two E-Rings [11], and
remove the Staple Jam Release
Gear [12], the Timing Belt [13] and
the Middle Gear 1 [14].
8. Remove the spacer and the spring
located behind the Staple Jam
Release Gear.
9. Remove the screw [15] and the
spring [16], and remove the Belt Ten-
sion Roller [17].