Field Service Ver. 1.0 Mar. 2005
2.1.3
Separation Roller
[5]
[3]
[12]
4582fs2509c0
[1]
4582fs2510c0
[2]
4582fs2511c0
[4]
4582fs2524c0
2. Periodical check
5. Remove C-clip (black) of the Paper
Take-up Roller, and remove the
Paper Take-up Roller [12].
NOTE
• Be careful not to lose the Pick-Up/
Take-Up Roller fixing pin.
6. To reinstall, reverse the order of
removal.
7. Select "Service Mode"
→
"Life" and clear the count of "ADF
Feed."
A. Replacing procedure
1. Unlock the Separation Roller Cover
locking claws, and remove the Sepa-
ration Roller Cover [1].
2. Remove the Separation Roller Assy
[2].
NOTE
• The Separation Roller Assy is of a
set-in type. Pinch the roller shaft at
both ends and pull out the Separa-
tion Roller Assy upward.
3. Remove the Holder [3] and the shaft
[4], and remove the Separation
Roller [5].
4. To reinstall, reverse the order of
removal.
→
"Counter"
7