4. Carry out the Cross Direction Adjustment. If the specifications are not met, loosen the
CCD Unit mounting screws and move the CCD Unit in the sub scan direction as neces-
sary.
☞ 232
NOTE
• Hold the CCD Unit by hand when moving it. NEVER use a screwdriver or similar
tool to tap to move it, as a varied distance between the CCD sensor and lens
results.
• When CCD unit is replaced, "Scan Calibration" and "Line Mag" Setting under Sys-
tem 2 available in Service Mode should be OFF.
6.3.12

Image Processing Board (PWB-C)

[1]
[3]
[5]
[2]
4037F2C034DA
[4]
[3]
4037F2C035DA
[5]
[6]
[5]
4037F2C036DA
1. Remove the Rear Cover and IR
Right Cover.
☞ 52
2. Remove the CCD Unit Cover.
☞ Refer to the step1 on page 126.
3. Remove four Screws [1], and remove
the IR Frame Protective Cover [2].
4. Remove three screws [3], and
remove the Original Size Detection
Sensor Assy [4].
5. Remove six screws [5], and remove
the Board cover [6].