5.2.2 Removing the Multifeeder Pickup Roller

1) Remove the durm unit.
2) Remove the developing assembly
(7.2.1 in Chapter5).
3) Remove the multifeeder tray.
4) Remove the 2 stepped screws [1] using
a screwdriver; then, keeping your
hands as shown, detach the pickup
guide assembly [2] by lifting it upward
to the front.
5) Remove the manual feed pickup roller
[3].
When Mounting
After mounting the multifeeder
pickup roller, rotate the
multifeeder pickup roller until
it stops, and check to make
sure that the cam [4] is as
shown.