5.5.4 CCD Test (2: CCD TEST)
A press on '2' on the keypad while the Test Mode menu is indicated will select CCD
Test mode. Press '4', '7', or '8' on the keypad in test mode for the following; do not use
other mode items, as they are for the factory/R&D:
'4' on Keypad
Use it to initialize the ADF read position parameter.
The settings will affect the following: service mode>#6 SCANNER>7. CCD>parameter
20, 22, 24 through 28, 30, 32, 34.
'7' on Keypad
Use it to initialize CS-related parameters.
The setting will affect the following: service mode>#6 SCANNER>7. CCD> param-
eters 1 through 8, 12.
'8' Keypad
Use it to execute gain auto adjustment, automatically correcting the CS output and set-
ting the CS parameters. (For details, see 2.4.2 of Chapter 13.)
COPYRIGHT© 2002 CANON INC.
2000
CANON iR1600/iR2000/iR1610/iR2010 SERIES REV.0 MAR. 2002