#0080 [TX]
The other party is not equipped with an ITU-T-compliant
subaddress reception function
Cause:
Bit 49 of DIS received from the other party is '0'.
Remedy:
(1) Transmit to a fax machine equipped with a subaddress function.
(2) Use normal G3 transmission.
#0081 [TX]
The other party is not equipped with an ITU-T-compliant password
reception function
Cause:
Bit 50 of DIS received from the other party is '0'.
Remedy:
(1) Transmit to a fax machine equipped with a password function.
(2) Use subaddress transmission that does not use a password.
(3) Use normal G3 transmission.
#0082 [RX]
The other party is not equipped with an ITU-T-compliant selective
polling transmission function
Cause:
Bit 47 of DIS received from the other party is '0'.
Remedy:
Ask the operator to set normal polling transmission, and use polling reception.
#0083 [RX]
Selective polling address or the password does not match during
ITU-T-compliant selective polling reception
Cause:
The selective polling address or the password of the machine does not match that of
the other machine.
Remedy:
Match the selective polling address and the password of the machine with that of
the other party.
#0084 [RX]
The other party is not equipped with a password function for ITU-T-
compliant selective polling reception
Cause:
Bit 50 of DIS received from the other party is '0'.
Remedy:
Use selective polling that does not use a password.