CHAPTER 7 FIXING SYSTEM
Hold the fixing roller gear [10],
and turn the fixing roller [11]
to see if the rotation is smooth
and that the busing [12] does
not move.
7) Prepare a strip from a transparency
(20cm in length and 20mm in width);
then, attach a coin (about 5g) to the
strip.
8) Insert the strip [14] between the ther-
mistor [13] and the fixing roller [11].
7-26
COPYRIGHT© 2002 CANON INC.
[11]
[11]
2000
CANON iR1600/iR2000/iR1610/iR2010 SERIES REV.0 MAR. 2002
[12]
[10]
F07-306-06
[13]
[14]