Lithium Battery (Bat1) - Canon iR1600 Series Service Manual

Hide thumbs Also See for iR1600 Series:
Table of Contents

Advertisement

Memory Clear List
If memory clear list is automatically printed when the machine is turned on,
Memo
you may assume that the image data it indicates has been lost without
backup. The image data storage status information is deleted as soon as the
list has been printed; see the following for a sample of the memory clear
list:
07/30/2001 17:52 FAX
TX/RX NO
MODE
0002
DELAYED TX
0002
DELAYED TX
0002
MEMORY RX
0002
MEMORY RX

5.1.3 Lithium Battery (BAT1)

The data backed up by BAT1 is control data on of user data or printer functions and ser-
vice mode settings.
Battery life : 5 yr (approx.)
When the battery reaches the end of its life, the display will indicate 'DATA ERROR'
when the power is turned on.
The battery cannot be replaced on its own. Upon exhaustion, the image processor PCB
itself must be replaced.
If you disconnect the jumper plug (JP1/JP201) from the image processor
PCB, and turn off the machine, all control data will be reset to default set-
tings. If you must disconnect JP1/JP201, therefore, be sure to print out the
control data, and enter the data after connecting JP1/JP201.
COPYRIGHT© 2002 CANON INC.
CHAPTER 8 EXTERNALS AND AUXILIARY CONTROL SYSTEM
*
*
*
*
*
*
* * * * * * * * * * * * * * * * * *
*
*
*
MEMORY CLEAR REPORT
*
*
*
*
*
*
* * * * * * * * * * * * * * * * * *
MEMORY FILES DELETED
DESTINATION TEL/ID
F08-501-01
2000
CANON iR1600/iR2000/iR1610/iR2010 SERIES REV.0 MAR. 2002
*
*
*
*
*
*
*
SET TIME
PGS.
1
07/30 13:51
1
07/30 13:51
1
07/30 13:53
1
07/30 13:54
001
ST. TIME
13:59
13:51
-----
-----
8-13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir2010 seriesIr2000 seriesIr1610 series

Table of Contents