Basic Sequence Of Operation (Laser Exposure System) - Canon iR1600 Series Service Manual

Hide thumbs Also See for iR1600 Series:
Table of Contents

Advertisement

1.2 Basic Sequence of Operation (laser exposure system)

Power switch ON
Laser scanner
motor(M102)
TOP signal(TOP*)
Laser
BD signal(BDI* )
COPYRIGHT© 2002 CANON INC.
Original placed/ADF
opened
Fixing roller
Start key ON
140˚C
STBY
INTR
WAIT*1
WMUP
WMUPR
*1: WAIT End Conditions:
: 25 sec or more passed after supplying power to the fixing assembly
and, in addition, the fixing assembly temperature is 150 or higher.
: 27 sec or more passed after supplying power to the fixing assembly
and, in addition, the fixing assembly temperature is 145 or higher.
F04-102-01
2000
CANON iR1600/iR2000/iR1610/iR2010 SERIES REV.0 MAR. 2002
CHAPTER 4 LASER EXPOSURE SYSTEM
PRINT
LSTR
STBY
4 - 3