CHAPTER 6 PICKUP/FEDING SYSTEM

5.1.3 Removing the Feeding/Separation Roller

1) Slide out the cassette.
2) Open the left lower cover.
3) Push down the separation roller [1] as
shown; then, pick the claw [2] of the
roller collar, and detach the separation
roller [1] and the feeding roller [3].

5.1.4 Removing the Cassette Pickup Solenoid

1) Remove the cassette pickup assembly
(5.1.1 in Chapter6).
2) Free the harness [1] from the harness
guide [2], and remove the screw [3];
then, detach the cassette pickup sole-
noid [4].

5.1.5 Removing the Paper Size Detecting Switch

1) Remove the screw [1], and slide out
the paper size detecting switch [2].
2) Disconnect the connector [3], and re-
move the paper size detecting switch
[2].
6-22
COPYRIGHT© 2002 CANON INC.
[2]
2000
CANON iR1600/iR2000/iR1610/iR2010 SERIES REV.0 MAR. 2002
[3]
[1]
F06-501-09
[1]
[3]
[4]
F06-501-10
[2]
[3]
[1]
F06-501-11
[2]