CHAPTER 7 FIXING SYSTEM
13) After putting back the fixing assembly,
check the resistance using a meter:
a. between the earth contact [21] and the
fixing roller core [22]
: it must be 350Ω or less
b. between the earth contact [21] and the
inlet guide [20]
: it must be 10Ω or less
7-28
COPYRIGHT© 2002 CANON INC.
[22]
[23]
2000
CANON iR1600/iR2000/iR1610/iR2010 SERIES REV.0 MAR. 2002
350
or less
10
or less
F07-306-10
[21]
[21]