Rated Outputs From The Power Supply Pcb - Canon iR1600 Series Service Manual

Hide thumbs Also See for iR1600 Series:
Table of Contents

Advertisement

CHAPTER 8 EXTERNALS AND AUXILIARY CONTROL SYSTEM

2.1.2 Rated Outputs from the Power Supply PCB

The levels of outputs form the DC power supply of the full-time ON system are as fol-
lows:
Output
Connector
Output voltage
tolerance
Rated output voltage
Rated output current
Activation level of
overcurrent protection
mechanism
The levels of outputs form the DC power supply of the remote ON/OFF system are as fol-
lows:
Output
Connector
Output voltage
tolerance
Rated output voltage
Rated output current
Activation level of
overcurrent protection
mechanism
*
The above levels apply when the AC input is between 85 and 135 V for the 120V model
and between 187 and 264 V for the 230V model.
8-4
COPYRIGHT© 2002 CANON INC.
3VS1
3VS2
CN1-11
CN1-15
CN1-13
CN1-17
CN2-8
CN1-19
CN2-9
CN1-20
CN5-5
CN5-6
CN5-8
±3%
±3%
3.45V
3.45V
4.3A
4.3A
8.0A
8.0A
T08-201-02
3VR
5VR
CN1-7
CN1-6
±5%
±5%
3.35V
5.05V
0.3A
1.0A
4.0A
3.0A
T08-201-03
2000
CANON iR1600/iR2000/iR1610/iR2010 SERIES REV.0 MAR. 2002
5VS
12VS
CN2-12
CN1-1
CN2-13
CN5-11
CN5-12
CN5-13
±5%
±5%
5.05V
12V
1.9A
0.6A
4.0A
3.0A
24VR1
24VR2
CN3-1
CN2-18
CN3-2
CN2-27
±5%
±5%
24V
24V
5.0A
5.0A
8.0A
8.0A