CI-5000 Film Recorder Calibration

A.
Electrical/Final Assembly Alignment of the CRT
Setup:
1.
Disconnect power cable from the Color Film Recorder Assembly.
2.
Remove Camera Post Assembly and Output Unit cover.
3.
Remove the six screws from the backplate of the Color Film Recorder Assembly.
Slide the backplate up one set of holes, so that the bottom holes in the backplate
line up with the middle holes in the case, and replace four screws. (This is to give
access to the back of the CI-5000 chassis.)
4.
Connect the Centronics cable #1A5556A between the parallel port of the CPU and
the 25- pin connector on the back of the CI-5000 (see Figure 4-1). Reconnect the
power cable.
Figure 4-1 Connecting CI-5000 to CPU with Centronics cable
4-4
Calibration Procedures