Polaroid ID-3000 Repair Manual page 168

Digital security and identification system
Hide thumbs Also See for ID-3000:
Table of Contents

Advertisement

Error
Message
No.
3157
Tape Component Never
Opened
3158
TAPE: Bad Field Reference
3159
TAPE: Field Count Mismatch
3160
Write Failure on Tape
3161
TAPECOMP.SOT Missing
3162
Physical Definition File
Missing
3163
TAPE: Field Name Mismatch
3167
TAPE: Drive Not Ready
3168
TAPE: Memory Allocation
Failure
3169
TAPE: Image Data Missing
on Tape
3170
TAPECOMP.CNF File
Missing
3171
Insert a New (Different) Tape
3172
Bad Format on Tape
3173
Tape Failure
3177
Checksum Failure on Tape
Probable cause
Missing or corrupted
TAPECOM.CNF file.
Index is wrong.
Internal error.
Write failure.
Missing or corrupted
TAPECOMP.SOT file.
Missing .PHY file.
Rewriting tape field
mismatch.
Tape drive is not ready or
loose cables.
Internal error code.
Internal error code.
Missing TAPECOMP.CNF
file.
Bad tape or full.
Defective tape.
Unable to access the tape.
Bad tape.
3-86
Corrective action
Reload or reinstall TAPECOMP.CNF
file in ID2DATA directory.
The database from tape and drive are
different.
Contact the Service Center.
Check the Read Only switch or tape.
Reload or reinstall TAPECOMP.SOT
file in the ID2DATA directory.
Reload APPS software.
Contact the Service Center.
Turn OFF the system, check all cable
connections to the tape and jumper
settings.
Contact the Service Center.
Contact the Service Center.
Reload or reinstall TAPECOMP.CNF
file in the ID2DATA directory.
Change tape and continue.
Re-tension the tape or use another tape
cartridge.
Re-tension the tape or use another tape
cartridge.
Insert new tape and start over.