Camera Offset Diagnostics

Problem
ID cards are not die cut
properly
Step 1:
Using two fingers, hold the film sheet up - position the film so that the picture number is in the
upper left corner.
Depending on which direction you want to move the ID cards, do the following:
Card 1 and card 2 positions are independent of each other. The variables
CARD1_XOFFSET & CARD1_YOFFSET determine the position of card 1; the position
of card 2 is determined by CARD2_XOFFSET, CARD2_YOFFSET.
Neither XOFFSET or YOFFSET of both card 1 and card 2 can have a negative value.
Changing the value of YOFFSET moves the card (either 1 or 2) horizontally. Both
CARD1_YOFFSET and CARD2_YOFFSET have the same value.The value of
XOFFSET affects the vertical position of either card 1 or card 2 accordingly (Figure 3-1).
The top corner of the film exposure area is:
CARD1_XOFFSET "0":
CARD1_YOFFSET "0";
The value of CARD2_XOFFSET depends on the X size of card 1. If the value of
CARD2_XOFFSET is large enough, it might expose a portion of the card which falls
outside of the image area, the exposure will stop and this message will be displayed in the
middle of the screen.
Attempted Frame Buffer Exposure Outside of Film Plane - 1
Probable Cause
Film sheet is not correctly
inserted into the die cutter
Software card position has
changed
and
Press Any Key to Continue
3-40
Troubleshooting/Diagnostics
Corrective Action
Reinsert the film sheet into the
die cutter; try upside down, then die
cut.
Using the Configuration Files
option in the Calibration & Setup
menu, do the following.