Polaroid ID-3000 Repair Manual page 118

Digital security and identification system
Hide thumbs Also See for ID-3000:
Table of Contents

Advertisement

Polaroid ID3000 Service Manual
Troubleshooting the CI-5000+ (Cont'd)
Problem
CI5000 performs self-
diagnostics but system
does not recognize it;
doesn't boot up
No image on film (black
image area)
Distorted image
Repeating spots on
image
Missing corners or
orange-red marks
on image
Broad streaks on
image
Muddy image, dull
colors
Dark corner on the
ID card
Probable Cause
SCSI connections are
loose
Film recorder SCSI
board is defective
Dark slide still inserted
in camera back
Electromagnetic
interference
Film pulled too quickly
from camera
Dirty developer rollers
in camera back
Yellow or white tab
pulled at an angle
Dirty developer rollers
in camera back
Hesitation during pull of
yellow tab
Insufficient development
time
4
COS
is low
3-36
Troubleshooting/Diagnostics
Corrective Action
Check all SCSI cables to make
sure they are properly connected.
Check F1 fuse on SCSI board;
replace fuse or SCSI board as
necessary.
Pull dark slide out of camera back
before starting exposure.
Move all electronic devices away
from film recorder. Color monitor
must be 12" from the film recorder
output unit.
Pull yellow tab at moderate speed.
Clean developer rollers.
Pull white and yellow tabs straight
out of camera back.
Clean developer rollers.
Pull yellow tab smoothly, straight
out of camera.
Develop image for recommen-
ded time (90 seconds for 2.3
software).
Refer to COS adjustment in the
Calibration section (page 4-10).