Polaroid ID-3000 Repair Manual page 138

Digital security and identification system
Hide thumbs Also See for ID-3000:
Table of Contents

Advertisement

Error
Message
No.
400
Serial Port Timeout
401
Serial Function Parameter
Error
402
No Serial Ports Found
500
Generic Memory Error
501
Memory Segment Error
502
Memory Count Error
503
Memory Allocation Error
510
Error Freeing Memory Block
511
Error Unloading Memory
Block
512
Error Adding Handle To
Uselist
513
EMS Detail Handle From
Uselist
514
Error Deleting Handle From
Uselist
Probable cause
Film recorder turned off or
serial cable disconnected.
Loose or broken serial cable
to film recorder.
Wrong CFR "ON/OFF"
setting in HOC_CI5K.CNF.
Serial board is not set-up
correctly.
Serial board is not set-up
correctly.
Corrupted EMS memory.
Corrupted EMS memory.
Corrupted EMS memory.
EMS out of memory.
Corrupted EMS memory.
Corrupted EMS memory.
Corrupted EMS memory.
Corrupted software.
Corrupted EMS memory.
3-56
Corrective action
Verify that film recorder is on and the
serial cable is connected.
Check serial cable and connections;
tighten connections or replace cable if
necessary.
Check CFR "ON/OFF" setting in
HOC_CFR.CNF and correct if
necessary. (See CNF files and Typical
Contents in Section 3.)
See Section 5 for proper board jumper
and switch settings.
See Section 5 for proper board jumper
and switch settings.
Check for and resolve hardware
memory conflicts or EMS driver
problems.
Check EMS driver memory address.
Check EMS driver memory
error.
Check available EMS size and run
EMSSTAT CLEAR from DOS if
necessary.
Check available EMS memory and
EMS driver.
Check available EMS memory and
EMS driver.
Check available EMS memory and
EMS driver.
Reinstall software.
Check for memory conflicts and check
EMS driver.

Advertisement

Table of Contents
loading