Terrestrial Interface Types; Eia-232 Specification - Comtech EF Data SDM-300L3 Installation And Operation Manual

Satellite modem
Table of Contents

Advertisement

SDM-300L3 Satellite Modem
Specifications
14.12

Terrestrial Interface Types

The following interface types are available with electrical properties indicated in the
following subsections:
Modem Configuration
25-pin Connector
34-pin Connector
37-pin Connector
50-pin Connector (W/Overhead
Board)
50-pin Connector
(Optional)
G.703: BNC-F and DB15 (DB15 for ASYNC)
14.12.1

EIA-232 Specification

Circuit Supported
Driver Amplitude (RXD, RXC,
ST, CTS, DM, DSR)
Receiver Amplitude (TXD,
TXC, RTS, LL, MC)
Impedance
Data Rate
EIA-232
X
X
X
X
X
X
X
TXD, TXC, ST, RXD, RXC, DSR, DCD, CTS, LL, RTS, MC
0 / Space / ON (True): 10V, ± 5V
1 / Mark / OFF (False): -10V, ± 5V
0 / Space / ON (True): Minimum +1V
1 / Mark / OFF (False): Maximum -1V
5000, ± 2000Ω < 2500 pF
9.6 to 120 kbps
TXD
Send Data
RXD
Receive Data
RTS
Request to Send
CTS
Clear to Send
DM
Data Mode
DSR
Receiver Ready
MC
Master Clock
LL
Local Loopback
ST
Send Timing
RXC
Receive Timing
TXC
Terminal Timing
MF
Mod Fault (TTL)
DF
Demod Fault (TTL)
14–31
EIA-422/
V.35
Overhead
EIA-449
X
X
X
X
X
Revision 0
MN/SDM300L3.IOM
G.703
X

Advertisement

Table of Contents
loading