SDM-300L3 Satellite Modem
Remote Control Operation
Receive
Command:
Signal Level
Response:
Status
Interface
Command:
Buffer Fill
Response:
Status
LNB Current
Command:
Monitor
Response:
Status
ODU Current
Command:
Monitor
Response:
Status
Current
Command:
Sweep Value
Response:
<add/RSL_'cr'
>add/RSL_xsnn.ndBm'cr''lf']
<add/IBFS_'cr'
>add/IBFS_nn%'cr''lf']
<add/LNBC_'cr'
>add/LNBC_nnn'cr''lf']
<add/ODUC_'cr'
>add/ODUC_nnnn'cr''lf']
<add/CSV_'cr'
>add/CSV_xsnnnnn'cr'
CD_yyy'cr''lf]
Where:
x = < or > (data modifier to indicate that the receive
signal level is less than or greater than the returned
value).
s = + or - (receive signal level sign, plus or minus).
nn.n = 0.0 to 99.9 (receive signal level magnitude).
Notes:
1. The 'x' (< or >) parameter is only returned if the level
has exceeded the computational resolution of the
system.
2.
'No Data' is returned if the level cannot be
calculated.
3.
Sampling' is returned if not enough data is currently
available to calculate the level.
Where: nn = 1 to 99 (relative to buffer depth).
Where: nnn = 0 to 500 (in 1 mA steps)
Notes:
1. The 'x' (< or >) parameter is only returned if the level
has exceeded the computational resolution of the
system.
2.
'No Data' is returned if the level cannot be
calculated.
3.
Sampling' is returned if not enough data is currently
available to calculate the level.
Where: nnn = 0 to 4000 (in 1 mA steps)
Notes:
1. The 'x' (< or >) parameter is only returned if the level
has exceeded the computational resolution of the
system.
2.
'No Data' is returned if the level cannot be
calculated.
3.
Sampling' is returned if not enough data is currently
available to calculate the level.
Where:
x = < or > (data modifier to indicate that the sweep offset
value is less than or greater than the returned value).
s = + or - (sweep offset from center).
nnnnn = 0 to 75000.
yyy = OK or FLT (decoder lock status OK or FAULT).
Notes:
1. The 'x' (< or >) parameter is only returned if the level
has exceeded the computational resolution of the
system.
2. 'No Data' is returned if the level cannot be calculated.
3. 'Sampling' is returned if not enough data is currently
available to calculate the level.