Comtech EF Data SDM-300L3 Installation And Operation Manual page 368

Satellite modem
Table of Contents

Advertisement

SDM-300L3 Satellite Modem
Remote Control Operation
AUPC
Command:
Minimum
Response:
Power Limit
Status:
Response:
AUPC
Command:
Eb/N0
Response:
Target Set
Status:
Point
Response:
AUPC
Command:
Maximum
Response:
Tracking
Status:
Rate
Response:
AUPC Local
Command:
Carrier Loss
Response:
Action
Status:
Response:
AUPC
Command:
Remote
Response:
Carrier Loss
Status:
Action
Response:
Remote
Notes:
Modem
1. Always wait 3 seconds between consecutive remote modem command/status polls.
AUPC
2. If Local AUPC is not enabled, status commands will return last known condition. They will also request status
Commands
from the remote modem. This allows a second request to return proper status.
Remote
Command:
AUPC
Response:
Enable
Remote
Command:
Interface
Response:
Substitution
Status:
Pattern
Response:
Remote
Command:
Interface
Response:
Baseband
Status:
Loopback
Response:
Remote
Command:
Interface
Response:
Read Error
Example:
Status
Command:
Response:
<add/MINP_snn.n'cr'
>add/MINP_snn.n'cr''lf']
<add/MINP_'cr'
>add/MINP_snn.n'cr''lf']
<add/ENSP_nn.n'cr'
>add/ENSP_nn.n'cr''lf']
<add/ENSP_'cr'
>add/ENSP_nn.n'cr''lf']
<add/MAXT_n.n'cr'
>add/MAXT_n.n'cr''lf']
<add/MAXT_'cr'
>add/MAXT_n.n'cr''lf']
<add/LCL_xxxx'cr'
>add/LCL_xxxx'cr''lf']
<add/LCL_'cr'
>add/LCL_xxxx'cr''lf']
<add/RCL_xxxx'cr'
>add/RCL_xxxx'cr''lf']
<add/RCL_'cr'
>add/RCL_xxxx'cr''lf']
<add/RPC_xxx'cr'
>add/RPC_xxx'cr''lf'
<add/RISP_xxx'cr'
>add/RISP_xxx'cr''lf']
<add/RISP_'cr'
>add/RISP_xxx'cr''lf']
<add/RBBL_xxx'cr'
>add/RBBL_xxx'cr''lf']
<add/RBBL_'cr'
>add/RBBL_xxx'cr''lf']
<add/RRES_'cr'
>add/RRES_nE-e'cr''lf']
<add/RRES_'cr'
>add/RRES_2E-6'cr''lf']
Where: snn.n = -30.0 to -5.0, in 0.1 steps (nominal range
in dBm).
Notes:
1. The nominal power range is modified relative to
the value specified by the modulator power offset
(MPO_).
2. ASYNC or AUPC Overhead only.
Where: nn.n = 3.2 to 16.0, in 0.1 increments (Eb/N0 in
dB).
Note: ASYNC or AUPC Overhead only.
Where: n.n = 0.5 to 6.0, in 0.5 increments (max tracking
rate in dBm/minute).
Note: ASYNC or AUPC Overhead only.
Where: xxxx = HOLD, NOM, or MAX (power level setting
when local carrier loss).
Note: ASYNC or AUPC Overhead only.
Where: xxxx = HOLD, NOM, or MAX (power level setting
when remote carrier loss).
Note: ASYNC or AUPC Overhead only.
Where: xxx = ON or OFF (remote AUPC enable).
Note: ASYNC or AUPC Overhead only.
Where: xxx = ON or OFF (remote transmit 2047 pattern
enable).
Notes:
1. Transmit 2047 Pattern.
2. ASYNC or AUPC Overhead only.
Where: xxx = ON or OFF (remote baseband loopback
enable).
Note: ASYNC or AUPC Overhead only.
Where:
n = 1 to 9 (error rate number).
e = 2 to 6 (exponent).
Notes:
1. Received 2047 Pattern.
2. AYNC or AUPC Overhead only.
This command returns 2047 BER from the remote AUPC
modem. If data is not valid, the message 'No_Data' is
returned in lieu of BER data.
A–16
Revision 1
MN/SDM300L3.IOM

Advertisement

Table of Contents
loading

Table of Contents