SDM-300L3 Satellite Modem
Remote Control Operation
Demod/
Command:
Decoder
Response:
Config.
Program
Status
<add/DCP_'cr'
>add/DCP_'cr'
SMT_xxxxxxx'cr'
IROT_xxxxx'cr'
MOM_xxxxxxx'cr'
BERT_xxxx'cr'
DT_xxxx'cr'
DDT_xxx'cr'
DF_nnnnn.nnnn'cr'
DR_nnnn_mmmm.mmm'cr'
DE_xxx'cr'
DEC_xxx'cr'IFL_xxx'cr' (Note 9)
SCF_snnnnn'cr'
SWR_nnnnnn'cr'
SR_xxx'cr'
ILT_xxx'cr'
ERF_nnnnn.n'cr'
BC_xxx'cr'
RCP_xxxx'cr'
BBL_xxx'cr'
ILB_xxx'cr'
ICFR_xxxx'cr'
IRFS_T1_ssss'cr'
IRFS_E1_ssss'cr'
IBP_xxx'cr'
IRE_xxxxxx'cr'
RDF_xxxx'cr'
ISCL_RX1_nnn'cr'
ISCL_RX2_nnn'cr'
RDP_xxxx'cr'
IDF_xxxxxx'cr'
(Note 1)
ICRC_xxx'cr'
(Note 1)
IBS _nnnnnn'cr'
BICA_dd;cc_dd;cc...'cr'
(Note 1)
DSR_xxx'cr'
RSDE_xxx'cr'
BW_RX1_nnn'cr'
(Note 2)
BW_RX2_nnn'cr'
(Note 2)
BW_RX3_nnn'cr'
(Note 2)
BW_RX4_nnn'cr'
(Note 2)
RXDR_xxxxxx'cr'
ROBR_nnnnn'cr'
(Note 3)
RCCL_n'cr'
(Note 3)
RCSB_n'cr'
(Note 3)
ROCP_xxxx'cr'
(Note 3)
RCT_xxxxx'cr'
(Note 3)
ENSP_nn.n'cr'
(Note 8)
MAXT_n.n'cr'
(Note 8)
RDA_xxx'cr'
IDRR_xxxxx'cr'
(Note 2)
IBSR_xxxxx'cr'
(Note 2)
RRSI_xx'cr'
R310_xxx'cr'
R315_xxx'cr'
LNB_xxx'cr'
LNBV_xxx'cr'
LNBR_xxx'cr'
LNBL_xxx'cr'
LNBH_xxx'cr''lf']
System Modem Type
Interface Receive Overhead Type
Modem Operation Mode
BER Threshold
Demodulator Type
Demodulator Decoder Type
Demodulator Frequency
Demodulator Rate
Descrambler Enable
Differential Decoder
Sweep Center Frequency
Sweep Width Range
Sweep Reacquisition
Interface Loop Timing
External Reference Frequency
Buffer Clock
Receive Clock Phase
Baseband Loopback
Interface Loopback
Interface Coding Format Receive
Interface Receive T1 Frame Structure
Interface Receive E1 Frame Structure
Interface Buffer Programming
Interface Read Error (RX 2047)
Receive Data Fault
Service Channel Level RX1
Service Channel Level RX2
Receive Data Phase
Insert Data Format
Insert E1 CRC Enable
Interface Buffer Size
Bulk Insert Channels Assignment
Demodulator Spectrum Rotation
Reed-Solomon Decoder
Backward Alarm Enable RX1
Backward Alarm Enable RX2
Backward Alarm Enable RX3
Backward Alarm Enable RX4
RX Driver Type
ASYNC Receive Overhead Baud Rate
ASYNC Receive Channel Character Length
ASYNC Receive Channel Stop Bits
ASYNC Receive Overhead Channel Parity
ASYNC Receive Communications Type
AUPC EBN0 Target Set Point
AUPC Max. Tracking Rate
Receive BPSK Data Ordering
IDR Receive ESC Type
IBS Receive ESC Type
RX Reed-Solomon Interleave Value
RX 8PSK 2/3 IESS-310 Operation
RX IESS-315 Operational Mode
LNB Power
LNB Voltage
LNB Reference
LNB Current Monitor Low Current Threshold
LNB Current Monitor High Current Threshold
This command is used by the EF Data M:N protection switch to
collect information that is necessary to configure back-up
modems. Because this command (content and/or order) can be
changed at any time by EF Data, it is advisable that other
commands ('DCS_' and 'ICS_', or 'BCS_') be used for M&C
systems.
A–23
Revision 1
MN/SDM300L3.IOM

Advertisement