Loma IQ2 User Manual page 94

Hide thumbs Also See for IQ2:
Table of Contents

Advertisement

The following options in the PV test setup menu allow you to specify the types of test that
should be performed during performance validation.
The test wands you specify for performance validation should have been determined using
sensitivity tests with the product after calibration
To specify the characteristics of
the PV test
V
until the No of passes
• Press
option is displayed and press
edit it.
^
V
• Press
or
number of passes of each specified
test wand that must be detected to
constitute a successful PV test and
e
press
to confirm it.
V
to display the Fe size
• Press
option and press
• Enter the size of ferrous test wand
which should be prompted for when
a PV test is initiated.
Likewise, set the NFe (non-ferrous)
and ST (stainless steel) sizes on the
subsequent two menus.
8024
e
to
to specify the
e
to edit it.
.
*No of passes
The number can be set between 1 and 8.
This should be set to a multiple of two so
that test wands can be placed at the leading
and trailing edges of the product.
*Fe size
The size can be 0.01 to 10.00 millimeters.
Setting the size to 0.00 will disable the
prompt during testing.
*NFe size
*ST size
Using Performance
2
2.00
2.00
2.00
77
Validation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents