The available options are summarised in the following table:
Options
Tracker
Reject time
Manual setup
Aux relay
Access ferrite
Rej out of run
Cal trigger
Dual frequency
Aux relay
*PV test
*Fault on PV
*Reverse mode
C
to exit from the User options menu.
• Press
To set up the reject options
Refer to Appendix E – Reject options, page 151.
C
to exit the Reject options menu.
• Press
11050
Description
This option will only appear if phot-eye operation has been selected in the
Configuration menu. Turn this ON or OFF as required.
Leave this at the default option of ON to enable access to the reject timing
information in the Product setup menu. Only set this to OFF once the reject
time has been correctly set, and you wish to deny line operators access to it.
Turn this ON or OFF as required.
Turn this to ERROR or RUN as required.
This entry must be set to YES, in order that a ferrite tune can be performed.
Turn this ON or OFF as required.
Turn this ON or OFF as required.
Set to YES to enable dual frequency operation, if it is a Dual frequency
detector.
Select operation as IN RUN, REJECT or DUAL as required.
NOTE: IN RUN is the default option unless the detector is dual frequency.
DUAL option will only appear when Dual frequency is set to YES. When
running Dual frequency no other setting can be selected.
Set to YES to enable the Performance Validation system.
Set to YES to cause the fault relay to operate if a Performance Validation
system test is not actioned or completed in the time allowed.
Set to YES to cause the detector to reject when there is no metal present in
the product. NO is normal operation. The menu entry will only appear if
photo-eye in the Configuration menu is set to YES.
143
Appendices