142
Appendices
NOTE: PEC is the abbreviation for Photo-electric cell (photo eye). PEC fault is only available
from software version IQ2V1.6.0.
The following table summarises the available tolerance settings:
Menu position
% of calibrated threshold added
MIN
15%
LOW
25%
MED
50%
HI
75%
MAX
100%
The Auto-calibration periods are summarised in the following table:
Photo-eye
Short
8 packs
Long
20 packs
Extra
n/a
long
C
to exit the Configuration menu.
• Press
Setting up user options
The detector must now be set up for the desired user options. Until you are completely
familiar with the operation of the detector, it is recommended that all the options are left at
their default values.
^
until the display shows User options.
• Press
e
to move into the User options menu, and then set up your options are
• Press
desired.
No photo-eye
20 seconds
1 minute
2 minutes
11050