Routine Maintenance - Loma IQ2 User Manual

Hide thumbs Also See for IQ2:
Table of Contents

Advertisement

132
Maintenance
Cleaning a diverter reject
• Isolate the electrical and air supplies to the metal detector.
• Release the swell latches or hand wheels (fixings may vary) on the removable access
cover and carefully remove. The door is attached to the main frame by a ground lead and
therefore cannot be completely removed.
• Remove the diverter bucket from its two location pins.
• Inspect the good and reject product chutes; clean as necessary. If the system is fitted with
a Test Ball collection system clean any residual product from the fitted mesh pieces.
• Using a mild detergent clean both the bucket and the inside of the housing thoroughly,
ensuring all residual product is removed.
• Thoroughly dry all washed components before re-assembly.
• Re-assemble the bucket, ensuring both pivot pins are correctly located in the drive arm.
• Replace the access cover ensuring the diverter pivot pin is correctly located into the
access cover bearing housing. Secure all the swell latches.
• Restore the electrical and compressed air supplies to the metal detector.
• Check the operation of the system by placing the test sample balls into the access door
located in the product pipe above the detector.

Routine maintenance

These procedures relate to all the metal detectors in the IQ
specified.
Warnings
The following safety warnings apply to these procedures:
1. LETHAL HAZARD – ELECTRICAL SUPPLIES.
2. LETHAL HAZARD – COMPRESSED AIR SUPPLIES.
3. WORKING ON EQUIPMENT.
4. REJECT DEVICES.
9. CONTAMINANTS.
See also the safety warnings relating to specific metal detectors in the Preface.
For details, see Safety warnings, page iii.