About the metal
detector range
Anti-vibration mounts are recommended for use only where the level of vibration is
significant and there is no metal in the metal-free area. Mounting on a Tufnol plate is often
more appropriate. This provides a rigid fixing and is non-conductive. Pivot mounting
simplifies the changeover of product and also cleaning of the detector. A pivot-mounted
(slimline only) detector must be supported at the end opposite the pivot to prevent vibration.
Technical specification
Mounting arrangement (Stand alone model)
Mounting arrangement (Short & Long frame
models)
Reject mechanism (depending upon model)
Power requirements
Universal input (Stand alone model)
UL approved control box
Short & Long frame models
UL approved control box
Current consumption
Environment
Operating temperature
Relative humidity
Installation category
Pollution degree
Maximum operating altitude
Air supply (Short & Long frame models)
Optimum supply pressure
Minimum air pressure
Maximum air pressure
Capacity (litre/second @ 4.5 bar (65psi)
Pivot, fixed or anti-vibration mount
Floor standing or ceiling hung
Cow bell diverter reject or voltage free contacts
85-264V, single phase, 50/60Hz
120V, 2A, single phase, 60Hz
220, 230 or 240V, single phase, 50/60Hz
120V, 2A, single phase, 60Hz
<50VA
-10°C to +40°C (-14°F to +104°F)
80% up to 31°C (86°F) reducing to 50% @ 40°C
(104°F)
Cat II
Pollution degree 2
2000m (6561')
4.0 bar (60psi)
3.5 bar (50psi)
4.5 bar (65psi)
10
5091