Loma IQ2 User Manual page 165

Hide thumbs Also See for IQ2:
Table of Contents

Advertisement

148
Appendices
Upon completion of the product calibration routine the derived working threshold will be
used unless the product signal initiates a change.
The following table describes the options on the Tracking menu:
Menu
Description
*Tracking
Turns the tracker
option on or off.
*Min limit
Lowest tracking limit.
*Max limit
Highest tracking limit.
*Max limit
Maximum limit value
lock/unlock.
*Adjustment
Factor by which the
threshold changes.
*Number of
Number of packs
packs
included in the tracker
calculations.
Advice
Can be set on a per product basis.
Commences at the calibrated working threshold.
The value cannot be set less than the calibrated
working threshold but may be increased up to the
value of the Max limit.
Commences at twice the calibrated working
threshold. The value cannot be set less than the
calibrated working threshold but may be increased
up to the value of your choice. However it is strongly
advised to set this value to just greater than the
typical amount by which the product signal is
expected to change. All signals that exceed this
value will be rejected.
Once the highest tracking limit value has been
entered the value can be locked to prevent a change
should a re-calibration occur.
The factor range is 0 - 9 where 9 is the largest. The
default value is 1.
The rolling pack number included within the tracker
calculations. The range is 1 -100 where 100 is the
finest control. The default value is 10.
11050

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents