To adjust the threshold
e
• Press
to edit the threshold.
^
• Press
and
increase or decrease the threshold
respectively and press
confirm it.
To adjust the compensation
V
• Press
until the display shows
Compensation and press
select it.
The display then shows the current
compensation and signal level
values.
e
• Press
to edit the compensation
value.
^
V
• Press
or
decrease the compensation
respectively and press
confirm it.
8024
(Continued)
V
keys to
e
to
e
to
to increase or
e
to
300
{
The threshold can be adjusted between 0
and 65535, in steps of 5, and defaults to
1000.
Compensation
-285
{
Setting up the metal
13
13
67
detector