134
Maintenance
Adjustment of the air pressure is normally carried out by pulling up the adjustment knob to
release the lock and by turning the control clock or anticlockwise the pressure can be
adjusted.
Removal of water from the water trap bottle is carried out by operation of a rotating knob or
by pressing a button. Either way the control will be located at the bottom of the water trap
bottle. Water should be removed regularly.
A typical regulator unit is shown for information:
PRESSURE
ADUSTER
INCOMING
AIR SUPPLY
90° ELBOW
FITTING
WATER
TRAP DRAIN
The correct setting of the air pressure can be found in the individual system specifications in
About the metal detector range, page 1.
Conveyor belt maintenance
Plastic modular belt conveyor versions – belt section replacement
• If product guides are fitted to the conveyor, unscrew the retaining screws and remove the
guides.
• Clamp the belt either side of one of the plastic hinge pins that are used to join the sections
of the belt together that require changing.
NOTE: If you do not clamp the belt it will roll off the loose sprockets when you remove the pin.
PRESSURE
GAUGE
10087